Hilic phenomenex
WebExionLC usando una columna Phenomenex Kinetex F5 (100 mm x 2.1 mm ID, tamaño de partícula 2.6 µm). El tiempo total del método fue de 20 min a un flujo de 200 µL/min. La fase móvil A era ácido fórmico al 0.1% en agua, y la fase móvil B era acetonitrilo con ácido fórmico al 0.1%. La temperatura del horno de columna fue de 40°C. WebApr 11, 2024 · 2 performing a quantitative analysis on the trisaccharide(4S) and the ΔIA in a product of the step 1, wherein in the quantitative analysis of the HILIC-MRM method for the trisaccharide(4S), a parent ion mass-to-charge ratio is 415.5, z=−2, and a daughter ion mass-to-charge ratio is 157.0; and in the quantitative analysis of the HILIC-MRM method for the …
Hilic phenomenex
Did you know?
WebHILIC: General Cleaning Procedure: 1. 50:50 Acetonitrile/Water for at least 20 column volumes or when normal pressure is observed. SEC/GFC: General Cleaning Procedure: 1. … WebPhenomenex offers the very best in Reverse Phase, Normal Phase, HILIC, Ion Exchange and Ion Exclusion columns. Better selectivity results in higher efficiency and retention ... HILIC is a particularly useful separation mode …
WebEntreprise * * * ... Web- A Novel HILIC Selectivity Zeshan Aqeel and Ryan Splitstone Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 90501 USA Introduction Traditionally, excipients are considered inert ingredients such as di-luents, fillers, binders, lubricants, coatings, solvents, and dyes used
WebMar 28, 2016 · The mobile phase (including buffer) we leave in the HILIC columns when they leave Phenomenex is suitable (preferred actually) for long term storage. This does not … WebDownload Now HILIC - Systematic Approach to Method Development First Name * Last Name * Company * What industry do you work in? Email Address * Country * Job Role * …
WebKinetex HILIC. Kinetex ® core-shell 2.6 µm and 1.7 µm particles were engineered to provide increased efficiencies and improved performance compared to traditional fully porous …
WebPhenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department by telephone, fax or email: … scrub tech program near meWebTip: HILIC works by retaining polar compounds into a water rich layer that is formed at the surface of the silica particle as a result of a polar stationary phase (Fig. 1) Fig 1. … pcnghw.com legitWebsame 2-µm frit used with larger columns. HILIC columns deliver nearly the same efficiency as the sub-2µm columns with better robustness. In this work, several applications of HILIC are transferred from totally porous columns (Agilent ZORBAX Rx-Sil, 5 µm, or RRHD HILIC Plus, 1.8 µm) to superficially porous Agilent Poroshell 120 HILIC columns ... scrub tech practice testWebPhenomenex™ Inc. Kromasil™ SFC-2.5-XT. Fused organo-silane on silica-CO 2 /MeOH with or without additives. ... Poroshell™ 120 HILIC. Bare silica. Acetonitrile/H 2 O/ 0.1 M Ammonium Formate. CO 2 /MeOH with or without additives. Agilent Technologies™ ... scrub tech orientation packetWebthe use of HILIC columns is a more effective technique over a tra - ditional reversed phase column to separate glucosinolates. The original method provided by ChromaDex ® … scrub tech picturesscrub tech programs utahWebNov 5, 2024 · To alleviate a number of these obstacles, Phenomenex has introduced a new SUGAR LC column that provides HILIC retention, separation, and sensitivity gains across a wide range of food and ... scrub tech programs in michigan